1. To disconnect Pads grey colour. |
|
2. By an ohmmeter to measure resistance between contacts �1� and �2�, it should be about 1 clod. If resistance differs from specified, it is necessary to replace the gauge. |
3. After that to measure resistance between contacts �1� and �3�, then between contacts �2� and �3�. In both cases the ohmmeter should show zero. If is though any resistance, to replace the frequency gauge. |
4. To check up conducting between колодкой the gauge of frequency and колодкой the block of management of ignition. For this purpose to disconnect from the block connecting колодку. |
|
5. By an ohmmeter to measure resistance between contacts �1� and �29�, then between �2� and �11� and, at last, between �3� and �28� (fig. of Number of contacts connecting Pads the management block see. |
6. Resistance should be equal in all cases to zero. If the ohmmeter shows any resistance, means in conducting there is a breakage. |